Primary injection test set
100 A–20 kA+ output; low voltage, seconds-to-minutes duty; portable single-box through modular high-current systems
Search by equipment, voltage, power, duty, condition or application.
100 A–20 kA+ output; low voltage, seconds-to-minutes duty; portable single-box through modular high-current systems
3/6 phase current outputs typically 0–60/100 A per channel; voltage 0–300 V; frequency/DC/transient simulation
Single-phase handheld through 3/6-phase automated systems; IEC 61850 GOOSE/sample values and GPS options
Handheld TTR through multifunction 12 kV insulation/impedance/winding systems; single/three-phase asset testing
50 V–15 kV test voltage; MΩ to multi-TΩ measurement; handheld, battery and mains-powered
0–5 kVac benchtop safety testers through 0–800 kVac field/lab sets; AC/DC and VLF variants
HF/UHF/acoustic/TEV; pC to nC sensitivity; portable, online and factory systems; cable/transformer/switchgear versions
1–16+ timing channels per phase; 1–4 breaks/phase standard, advanced systems for air-blast/GIS; travel and resistance options
2 V cells through 1,500 V systems; conductance/impedance/capacity/load testing; handheld to automated discharge banks
LV telecom through 500 kV power cable; TDR, surge, arc reflection and acoustic pinpointing; portable or van systems
80×60 through >1,000×1,000 detector classes; -40 to >2,000°C; handheld, fixed and drone payloads
0.01 Ω to >200 kΩ; 2/3/4-pole, clamp and selective methods; handheld and high-current systems
mA leakage to 3,000 A AC/DC; 600–1,500 V; flexible Rogowski and conventional jaws
3.5–8.5 digit; mV to 1,500 V; µA to 20 A direct; handheld, bench and intrinsically safe variants
2–8+ channels; 20 MHz–100+ GHz; 8–16+ bit; handheld, bench and isolated power-analysis variants
CT ratio/knee/excitation and VT ratio tests; 1 A/5 A CT; secondary injection to high-voltage laboratory systems
0–200 kV peak common; 0.01–0.1 Hz; cable classes from 5 to 138 kV depending system
250 V–15 kV; MΩ to multi-TΩ; handheld to advanced diagnostic units with PI/DAR/step voltage
10 kW–7 MW modular/rental systems; 120 V–35 kV via transformer; resistive, reactive or combined
Portable analyser through permanent monitoring; electrical power, waveform, vibration, insulation and load-bank integration
Electrical calibrators from µV/µA to 1,000 V/100 A; process, pressure, temperature and multifunction standards
Single-sensor temperature/moisture through multi-gas DGA and full asset monitors; LV auxiliary, utility communications
Single motor current/vibration sensor through plant-wide wireless systems; fractional kW to 100 MW assets
1–64+ channels/rack; proximity, velocity and accelerometer inputs; API 670 machinery protection and portable analysis