CategoriesBusway & PDUPlug-in busway
Busway & PDUTF-0339

Plug-in busway

25–6,300 A; LV and selected MV; tap spacing and live plug-in options

Core catalogue3 sourcing pathsHigh/medium confidence

Distributor stock for standard PDU/tap units; engineered busway runs and high-current systems by RFQ

Source this product family →

Catalogue research, not a live stock claim. Rating, compliance, availability and commercial terms are confirmed with the responding supplier.

Choose how specific you need to be

One family. Three clear paths.

Start with the closest path—your exact rating and project constraints are captured in the sourcing request.

01
Standard / commonly boughtFastest route for common needs
+

Rating / size scope

25–6,300 A; LV and selected MV; tap spacing and live plug-in options

Configuration

Copper/aluminium; feeder or plug-in; sandwich or air-insulated; straight/elbow/tee/tap units; floor/rack/remote PDU; basic, metered, monitored or switched.

Typical sourcing route

Verified distributor/OEM route; engineered runs and high-current systems are RFQ

Start with this path →
02
Engineered / upper-endConfigured with OEM or integrator
+

Rating / size scope

Upper end or non-standard configuration within/near this published market range: 25–6,300 A; LV and selected MV; tap spacing and live plug-in options

Configuration

Custom voltage/current/interface, enclosure, cooling, dimensions, protection, site code or integration within the product family.

Typical sourcing route

Engineered OEM/integrator RFQ

Start with this path →
03
Niche / exact-matchManual hunt for rare or legacy fit
+

Rating / size scope

Exact rare, certified, obsolete or application-specific configuration; commercial boundary: 25–6,300 A; LV and selected MV; tap spacing and live plug-in options

Configuration

6,300+ A busway; medium-voltage busduct; isolated-phase generator bus; 400–800 Vdc data-centre distribution; 100+ kW rack PDU; marine/rail; exact tap-off compatibility.

Typical sourcing route

No exact niche seller verified in this research pass

Start with this path →
Required for a useful quote

What suppliers need.

  • Type
  • current
  • voltage
  • phase
  • frequency
  • conductor
  • short-circuit rating
  • enclosure/IP
  • length/layout
  • tap/outlet configuration
  • metering
  • standards
Research boundary

Reference data, clearly labelled.

Verified distributor/OEM route; engineered runs and high-current systems are RFQ

IEC 61439-6; UL 857; IEC 60364; applicable data-centre and fire standards

Need the legacy, certified or exact-footprint version?

Let TANNFELD run the manual hunt.

Post exact requirement →
COMPANY VERIFICATIONSTRUCTURED SPECIFICATIONSSEALED PROPOSALSSECURE INTRODUCTIONS